OVERVIEW
The CEL-350 dBadge is ideal for personal noise exposure measurements
around the workplace.The dBadge design eliminates cables and weighs only
68g. No other external equipment is needed to operate the CEL-350 dBadge.
It is simply operated by the 2 keys on the side of the instrument. All
necessary workplace noise parameters are measured and stored
simultaneously, for later download to a PC, no set-ups are required and
no risk of measuring the wrong parameters. Battery life and memory
capacity are sufficient to perform many consecutive shift measurements
without charging or downloading. The CEL-350 dBadge very easy to fit to
the shoulder of the employee and comfortable to wear.
FEATURES
| Compact, rugged design weighs only 68g |
| No cables to damage or get in the way |
| Measures and logs all workplace noise parameters |
| 32 hour battery life, fully charges in 90 minutes |
| Integrated display and visual exposure alarm |
| Simple auto-calibration function |
| Comprehensive software package |
APPLICATIONS
| Measuring personal noise exposure |
| Assessing and monitoring noise in the workplace |
| Ensuring compliance with Workplace Noise Regulations |
DISPLAY
Display shows measurement status and data
|
Unique LED action level alarm function |
|
‘Fuel gauge’ display for memory and battery information |
|
1 minute values of average and peak noise levels stored |
The CEL-350 is the first compact noise badge product to be designed
with a display. This internal display makes it easy to perform
calibration, provides status information and shows key measured data.
The dBadge has a unique ‘fuel gauge’ to display memory and battery
status, ensuring the exact remaining battery and memory capacity can be
viewed on the display. Also a unique feature of the dBadge is the alarm
function. An ultra-bright LED on the dBadge gives a visual indication of
when exposure action levels have been exceeded by flashing at different
rates. These action levels can be configured via the dB35 software and
used to instantly see if noise control or hearing protection measures
are needed. The alarm function can be switched on or off via the dBadge
keys.
In addition to noise exposure parameters, the time history of the noise
is logged in 1 minute values of both the average noise level and the
peak value for subsequent analysis of how the noise exposure has
occurred. This data can be viewed and analysed via dB35 software.

SIMPLE
2 KEY OPERATION
The CEL-350 dBadge is quick and easy to operate. After switching the
dBadge on, place the calibrator over the microphone and the CEL-350
dBadge will auto-calibrate, and store the calibration data and time,
ensuring accurate and validated results. The unique design of the
windshield ensures it can be securely clipped into place to give
protection in dusty environments and prevent air movement affecting the
measurement. The dBadge can be started and the keypad locked before
being placed on the shoulder of the employee. Overall, a measurement can
be started within seconds of
switching the dBadge on. At the end of the measurement run, simply
unclip the dBadge. The data can be viewed on the easy to read graphic
display to ensure the noise measurement was valid.
Consecutive measurements can be taken without the need to charge or
download the dBadge.
SOFTWARE
| Store results in simple tree structured database, by person, place or
process etc |
| Automatically colour codes results for exceeded noise action levels |
| Graphical display and analysis of noise time history |
| Automatic report generation |
| Data can easily be exported to other applications |
The dBadge downloads to a PC automatically using dB35 software, simply
by pointing the dBadge at the infra-red download cable provided. Once
downloaded, data can be stored under an employees’ name, location or
process so that a database of noise exposures can be built up.
An automatic colour coding system can be used to highlight which
employees have been exposed to specific noise action levels. The time
history of the noise exposure is displayed graphically and can be analysed
to
see when the majority of an employees’ exposure has occurred.
Report templates provided with the software can be customised and saved,
so that user-defined reports can be easily generated.
Data can be viewed according to different measurement protocols, either
ISO (Europe) or OSHA (USA). Alternatively the data displayed can be
customised to a specific users own requirements.

SPECIFICATIONS
| Technical: |
| Linear operating range: |
|
| Peak measurement range:
|
95.0 to 143.0dB Peak |
| Frequency weightings RMS:
|
A |
| Frequency weightings Peak: |
C, A, Z (Linear) |
| Time weightings: |
Slow, Fast & Impulse |
| Amplitude weightings:
|
Q=3 & Q=5 |
| Selectable thresholds : |
2 (70 to 90dB),
selectable in 1dB steps |
| Selectable criterion:
|
1 (70 to 90dB), selectable
in 1dB steps |
| Memory capacity: |
64kB (180 Hours of
measurements) |
| Default modes: |
ISO or OSHA |
| Calibration information: |
Calibration dates, times
and levels |
| Security: |
Lock via keys |
| Power supply: |
Internal NiMH cells |
| Battery life: |
32 Hours run
capacity |
| Size mm : |
72x47x52 inc windshield |
| Weight g : |
68 |
Data storage:
|
Non-volatile, 10 years of
storage |
| Display: |
Graphic LCD 96 x 26 pixels |
| Output (PC): |
Infra-red download
cable (supplied) to
dB35 software |
| Applied Standards: |
IEC 61252:2002 Personal
Sound Exposure Meters
ANSI S1.25:1991 Personal Noise Dosimeters |
| Measured
Parameters: |
| ISO: |
LAeq, LCpeak, LAEP,d,
Pa2Hours |
| OSHA: |
LAavg (Q=5), LZpeak,
LASmax, %dose (Q=5), TWA
(Q=5) |
| General: |
LAFmax, LAFmin, LASmin |
| (via dB35) |
LAIeq, LAImax, LAImin, LApeak |
| Time history: |
LAeq, LZpeak, LCpeak,
LAavg (Q=5) Stored as 1
minute values |
| Storage: |
All parameters
simultaneously stored |
| Environmental
Conditions: |
| In storage: |
Temperature: -10 to +50oC, |
| Humidity: |
30 to 95% RH
(non-condensing)
In operation: Temperature: 0 to +40oC |
| |
| Casella CEL
have a continuous product improvement policy and therefore reserve the
right to change the specification without notice |